AMS 4711 - Pressure transmitter with voltage output 0-5V by AMSYS

AMS 4711 – Pressure transmitter with voltage output.
Here in the version as absolute pressure sensor with only one pressure port.

Electrical connection of AMS 4711 by AMSYS

Electrical connection of AMS 4711

The AMS 4711 sensor is part of a series of miniaturized analog pressure transmitters* ready for use. AMS 4711 is designed for fast screw assembly in a harsh industrial environment or HVAC applications like aircleaners and fits for absolute, differential, gage and bidirectional differential pressure measurement.

One process of AMS 4711 production is the calibration as well as the compensation of temperature dependent drift of offset and span. No additional adjustment on the part of the customer is necessary. The sensor provides a 0…5 V output signal at 8 – 36 V voltage supply.

An integrated CMOS-DSP and EEPROM allow high accuracy in measurement capability. AMS 4711 comes in a robust and compact plastic package (IP67) and is unilaterally mediaresistent due to underside pressurization*.

Pressure types and ranges for the AMS 4711

AMS 4711 (ultra low pressure) pressure ranges: differential or bidirectional differential: 0-5;  0-10 mbar or ±5 and ±10 mbar

AMS 4711 (low pressure) pressure ranges: differential or bidirectional differential: 0-20; 0-50; 0-100 mbar or ±20; ±50 and ±100 mbar

AMS 4711 pressure ranges: gage, differential or bidirectional differential: 0-200; 0-350; 0-1000 and 0-2000 mbar or ±200; ±350 and ±1000 mbar

AMS 4711 pressure ranges: absolute 1000 and 2000 mbar

AMS 4711 pressure range: barometric (absolute) 700-1200 mbar

Note: The AMS 4711 can also be calibrated to meet customer specifications. Further variants of the transmitter family are the AMS 4710 with a 10 V output, the AMS 4712 with a fault-resistant 4-20 mA output and the AMS 3011 in a rugged metal housing for high system pressure*.

Accessory

Connection cable for pressure sensors AMS 471X: Related M5 cable

Features

  • High accuracy in measurement
  • Low total error between -25…+85ºC
  • 0…5 V-Output signal
  • Wide range of supply voltage
  • Dust-and-water-tight (IP67)
  • Maintenance-free
  • Product “Made in Germany”
  • Simplest installation, quick start of operation
  • RoHS and REACH compliant

Applications

  • Barometric measurement
  • Monitoring of industrial filters
  • HEPA filter control
  • Pneumatic control
  • Monitoring of vacuum, Heating, Ventilation and Air Conditioning (HVAC)
  • Over- and under pressure measurement

For information on prices and delivery times or if you have any technical questions, please contact info@amsys-sensor.com.